Availability: | |
---|---|
Quantity: | |
MY-B147G
The three-category fully automatic blood analyzer is a device used to analyze human blood samples. It can automatically perform measurements and analysis of three basic blood parameters: white blood cell count, red blood cell count, and hemoglobin level. This instrument is typically utilized in medical laboratories, hospitals, clinics, and research institutions for assessing the blood condition of patients.
Product Advantage:
High Throughput: They can process a large number of samples quickly, making them ideal for high-volume laboratories.
Accuracy and Precision: Automated systems minimize human error, ensuring more reliable and reproducible results.
Versatility: They can perform a wide variety of tests, including blood glucose, cholesterol levels, liver function, and kidney function tests.
Cost-Efficiency: Automation reduces the need for manual labor and lowers the overall operational costs.
Product Uses:
Clinical chemistry tests (e.g., blood glucose, lipid profiles)
Monitoring of metabolic disorders (e.g., diabetes)
Liver and kidney function tests
Toxicology and drug testing
Product Operate Guide:
The operation of the machine is not done once and for all, and it is necessary to pay special attention to the state of the machine during each packaging process. In order to effectively manage and maintain the packaging machine and control the product quality, in addition to regular maintenance, the auxiliary personnel and feeding personnel of the equipment also need to follow the following operating procedures.
Auxiliary personnel
Turn on the power switch
Check whether the air pressure is sufficient (must reach 0.6Mpa)
Click the host to start, and check whether each action is working properly
Check and clean up each box room
Put the bag, load the material, put the material box
Click the host to start
The product that is packaged in vacuum for the first time should be checked whether the seal is firm, whether the suction is tight and through the water check(Must check vacuum chamber 1-10)
During the production process, check the product sealing and pumping conditions continuously
Every 2 hours after the machine runs, must be the top cover of the machine, bag clip, and funnel mouth, carried out with an air gun clean
The bag or material dropped on the machine, should be hooked out with a hook, do not take it by hand
Specifications:
Detection method: Photometric detectior
Measurement:157.5*145.7*64.6mmi
Detection time ≤3min
Weight:622g
cv:≤ ±10%
Data storage:3000 results
Sample type:Peripheral or venous blood or serum
Display:4.3touch screen
Sample volume :≤ 45 uL
Adapter input AC100-240V.50/60Hz30VA, output5V,2A
Power supply :Adapter input AC100-240V.50/60Hz30VA, output5V,2A
Bult-in Lithium battery: DC3.7±0.3V
Storage environment :Temp:20 C~60 ℃; Rh:10% ~90% Operation environmen:Temp:15℃ ~35℃; Rh:<85%
Overall Performance
Equipment type Fully automatic discrete, STAT priority
Analysis rate Constant speed 160T/H (without ISE)
Test principle Colorimetry, turbidimetry
Analysis method End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
Sample System
Sample Tray 42 sample positions, random access of all samples
Sample Volume 2-50ul, 0.1ul increment
Sample probe Liquid level detection, the remaining detection, collision protection etc.
Sample Containers Sample cups, Micro tube, Original blood-collection tube, etc.
Reagent System
Reagent Tray 25 reagent positions
Reagent Volume R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration 4-15℃, independent power supply, 24-hour non-stop refrigeration
Reaction System
Reaction Tray Rotating tray, 120 cuvettes
Cuvette Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume 180-500ul
Incubation system Bi-directional liquid-air device
Temperature 37℃±0.1℃ with real-time display
Optical System
Light source 12V35W halogen lamps, over 2000 hours
Photoelectron road after spectrophotometry
Wavelength 340,405,450,510,546,578,630,700nm
Absorbance range 0-3.500Abs
Resolution 0.0001Abs
Operating System
PC operating system Windows XP or above
Analysis control software English version graphical operating software
Report printing Report formats support the user-defined mode, QC and state information etc.
System connection RS-232
Working Conditions
Power supply AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature 15-30 ℃
Humidity 35-80%
Water consumption 5L/Hour
Dimension Bench top: 750mm*520mm*600m
Analysis system
Working mode: Discrete/random access
Test speed: test speed 180T/H (without ISE)
Test principle: Absorbance photometry, Turbidimetry
Methodology:End-point, Fixed-time, Kinetic, Single/Dual
reagent chemistries, monochromatic/bichromatic
Linear/non-linear multi-point calibration
The longest reaction time: 15 minutes
Minimum reaction volume: 150μl
Cuvettes material: plastics (quartz glass can be selected), 81
cuvettes have the function of automatically deducting reagent
and sample blanks
Linear range of absorbance: 0-3.8Abs
Halogen light source life time ≥ 2000 hours
Wavelength:340nm、405nm、450nm、510nm、546nm、
578nm、630nm、670nm
Refrigeration system: water medium uniform refrigeration
technology
Reagent storehouse temperature: 4-16℃
Reaction temperature: 37±0.2℃
Temperature fluctuation: ±0.1℃
Working Conditions
Temperature: 10℃ ~30℃
Humidity: ≤85%
Maximum Water Consumption:<12L
Power Supply: 200~240V 50/60HZ 600W
Dimension:834mm(w)×643mm(D)×756(H)
Net weight: 65KG
Gross weight: 98KG
PRODUCT FEATURES:
Mini Fully Auto Chemistry Analyzer Discrete/random access
STAT sample priority
asy to use
Internal computer with 13”displayer All-in-one machine
Automatic Washing
No Washing (Option : 150 B)
Test speed : Constant 150T/H
Dimension : 352mm(L)*600mm(W)*385mm(H)
Net weight : 27.8KG
REACTION:
40 cuvettes
25 sample positions+5 original tube
50 positions for reagent with cooling system
REAGENT:
25 bottles with volume of 6ml
25 bottles with volume of 24ml
LED light source with 8 channel transmissometry
SAMPLE HANDLING:
Liquid level detection / Collision protection
WORKING CONDITIONS:
Temperature:10~30℃
Humidity: ≤85%
Power Supply: AC 100~240V 50/60HZ
Water Consumption: ≤5L/H
Reaction/Reagent/Sample Handing:
81 cuvettes
24+5(Tube 12*100) sample positions
1 calibration position / 1 QC position / 1 ST position
54 positions for reagent
27 bottles with volume of 8ml
27 bottles with volume of 24ml
LED light source with 8 channel transmissometry,Rear
Spectrophotometry
Extra 1 channel scattering (Option : SL120 C)
Liquid level detection / Collision protection
High pressure water flush interior the probe
Working Conditions:
Temperature:10℃ ~30℃
Humidity: ≤85%
Power Supply: 100~240V 50/60HZ
Water Consumption: <5L
Test speed : Constant 120T/H
Dimension : 305mm(L) x 605mm(W) x 330mm(H)
Net weight : 22KG
Parameters:
Throughput:60 Tests/hour
Assay ltems:5 parts, 29 parameters, 3 histograms, 3D scattergram
Principle:Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, lmpedancemethod for RBC and PLT counting, Cyanide free reagent for HGB test
Parameters:WBC, RBC,HGB,HCT,MCV,MCH,MCHC, RDW-SD, RDW-CV, PLT,MPV, PCT,PDW,P-LCRP-LCC,NEU%,LYM%,MON%,EOS%,BAS%,NEU#,LYM#,MON#,EOS#,BAS#4 Research parameter: ALY%,ALY#IG%IG#
Sample Volume:CBC+DIFF mode: S20ul
CBC mode: <10ul
Storage:100,000 results including histogram, scattergram and patient information
Interface:4 USB ports, 1LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader.
Power Supply:AC220V+10% 50/60Hz;110V+10% 60Hz;400VA
Package Size(W*D*H):670*590*790mm
Gross Weight:53kg
Reagent Package Size:330*330*330mm,400*290*240mm,400*290*240mm
Reagent Gross Weight:22kg, 2kg, 1kg
Throughput 60 samples/hour
Principle Tri-angle laser scattering and sheath flow for WBC differentiation and count, Impedance for RBC and PLT count, Colorimetry for HGB count
Aperture diameter RBC/PLT chamber: 70um
Parameters 26+4 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB,
HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW-CV, PDW-SD, PCT, P-LCR, P-LCC, ALY%, ALY#, LIC%, LIC# (RUO)
Histograms 4 scattergrams, 2 histograms (including RBC, PLT histograms)
HGB lamp LED 530nm
Sample volume Whole blood mode: 20ul, Pre-diluted mode: 20ul
Unique design Built-in barcode scanner (Optional)
Calibration Manual, auto and fresh blood calibration
Counting modes Whole blood, capillary whole blood and prediluted
Sample analysis CBC+DIFF, CBC
Print Auto and manual print
Blockage clear High voltage, high pressure flush
Language English, Spanish, French, Portuguese, Italian and Russian
LIS connection Support Bi-directional LIS connection
Communication protocol HL7
Printer language PCL6
Storage 60,000 results with histograms
Reagent Standard configuration: Diluent/20L, DIFF Lyse/500ml, LH Lyse/200ml (2 Lyses inside the analyzer)
Cleanser Standard configuration: Probe cleanser/50ml
Input 10.4-inch touch screen, support mouse, keyboard, external barcode scanner
Output Built-in thermal printer, support external printer
Printer paper Φ50mm*58mm
Interface 1 DB9 serial port, 4 USB ports, 1 Network port (compatible with TCP/IP protocol)
Dimension 430(D)mm x 350(W)mm x 435(H)mm
Net weight 28KG
Work temperature 10-30°C
Power requirement 100~240 AC, 50/60Hz, 200VA
Relative humidity ≤85﹪
Atmospheric pressure 70.0kPa-106.0kPa
Detection of Reticulocyte
Quantitative detection of RET for capillary blood and
predilution blood.
Up to 7 report parameters.
Provide clinical reference information of RET maturity,
anemia treatment monitoring, and differential diagnosis.
Optical Platelet Detection
RET Detection with PLT-O parameter.
PLT-O ensures results more accurate through staining,
to avoid interferences.
Detection Technology:Fluorescence Staining & Flow Cytometry
Detection mode:
CBC
CBC+DIFF
CBC+RET
CBC+DIFF+RET
Sample mode:Whole Blood Mode, Low Value Leukocyte Mode, Predilution Mode, and Sample Research Mode
Sample volume:
Whole blood mode: 88ul
Predilution mode: 70ul
Throughput:
CBC+DIFF: 100T/H
CBC+RET: 83T/H
CBC+DIFF+RET: 83T/H
Reporting parameters (36 in total):
Leukocyte: WBC、NEUT(#,%)、LYMPH(#,%)、MONO(#,%)、EO(#,%)、BASO(#,%)、IG(#,%)
Erythrocyte: RBC、HGB、HCT、MCV、MCH、MCHC、RDW-SD、RDW-CV、NRBC(#,%)
Platelets: PLT、PDW、MPV、P-LCR、P-LCC、PCT
Reticulocyte: RET(#,%)、 IRF、 LFR、 MFR、 HFR、 RET-He
Linear range:
WBC: 0~500x109/L
RBC: 0 - 8.60×1012/L
HGB: 0 - 260g/L
PLT: 0~5000x109/L
Features:
5-part differentiation, 27 parameters, 3 DIFF scatter grams and 1 BASO scatter gram, 3 histograms for WBC, RBC and PLT.
Tri-angle semi-conductor Laser scatter combined with chemical dye method, advanced flow cytometry
Compact, powerful and affordable
Only 15ul sampling volume
Up to 60 samples per hour
3 counting modes: venous blood, capillary blood and pre-diluted
Capability to flag abnormal samples
Large storage capacity: up to 50,000 samples
Technical Specifications:
Principles
Impedance method for WBC, RBC, PLT counting
Cyanide-free reagent for Hemoglobin test
Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, independent Basophil channel
Parameters
WBC, Lym%, Lym#,Mon%, Mon#,Neu%, Neu#,Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT, and 4 research parameters LIC%, LIC#, ALY%, ALY#
3 DIFF scatter grams and 1 BASO scatter gram, 3 histograms
Throughput
Up to 60 samples per hour
Sample Volume
Whole Blood: 15ul, Pre-diluted: 20ul
Test Mode
CBC CBC+DIFF
Performance
Carryover Repeatability Linearity
WBC ≤0.5% ≤2.0% (4-15×109/L) 0.00-300×109/L
RBC ≤0.5% ≤1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L
HGB ≤0.5% ≤1.5% (110-180g/L) 0-250g/L
PLT ≤1.0% ≤4.0% (150-500×109/L) 0.00-3000×109/L
Data Storage Capacity
Up to 50,000 results including numeric and graphical information
Communication
LAN port supports HL7 protocol
Operating Environment
Temperature: 15oC-30oC
Humidity: 30-85%
Air Pressure: 70-106 kPa
Power Requirement
A.C. 100-240V, ≤300VA, 50/60Hz
Dimension and Weight
360mm(L) × 470mm(W) × 430mm(H)
Weight: 28kg
Parameters:
5-part WBC Differential
25 Reportable Parameters
2 Histograms
2 Scatter Grams
Abnormal Sample Alarm
Sample Mode:Whole Blood (Venous/Capillary), Pre-dilution
QC Methods:L-J QC, X-B QC
Power Supply:100-240 V~ 50/60 Hz
Weight:21 kg
Dimension:328 mm x 471 mm x 446 mm(LxWx H)
Data Storage:10000
Screen Type:10.4 inch Resistive Screen
Operating Conditions:18~30"C, <80% Relative Humidity, 75 kPa~106 kPa
Function: Automated WBC 3-differential, 22 parameters with 3 color histograms (WBC, RBC, PLT)
Principal: Electronic impedance, SFT method for hemoglobin
Throughput: ≥60T/H
Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood
Sample Volume: Anticoagulant whole blood ≤9.6µL, Anticoagulant capillary blood ≤9.6µL, prediluted capillary blood ≤20µL, the sample volume for repeating two times testing and avoiding second sampling
Working Mode: Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and making second diluting automatically
Block-clearing: Soak and washing back and forth, high pressure burning. Boast the function of monitoring incomplete blockage
Alarm: Automated system diagnosis, self testing, fault alarm and reagent shortage alarm
Automated Maintenance: Automated washing during power on and power off, reducing the blockage rate
Standby Protection: 24 hours switch on, automatic sleep and wake up function
Storage: Large quantity test results storage, at least 400 thousand test results with comprehensive information. Extended SD memory supported.
Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration Mode: Manual and automatic calibration available. Fresh blood calibration available also.
Reference Value Setting: Many reference value ranges (children, adult and the aged). The appropriate reference value range could be automatically selected according to the inputted age and sex.
Discriminator Function: Float and fix discriminator. Manual adjust available
Display: TFT LCD (Optional Touch Screen)
Input Mode: Standard mouse and keyboard. Optional bar code reader
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Report Format: Many kinds of report format (not less than 8 kinds)
Reagents System: Open reagent system. No cyanogen reagents
●3-part differentiation of WBC, 23 parameters, single channel counter
●Volume measurement by time ,not wrong warning
●Adanced valve technology,long life
● RS232 interface, PC connecting
up to35/ 60 samples test per hour
● Electrical resistance for counting and SFT method of hemoglobin
● Low sample consumption : venous 9.8 ul, capillary 9.6 ul, pre-diluted 20 ul for twice testing one time
● 8.4” color TFT, Windows interface all testing parameter displayed simultaneously
● Windows operation system graphical buttons mouse and keyboard operation
● Double convolution and intelligent fitting
● Automatic diluting , Mixing , rinsing and clog clearing
● Automatically sample probe cleanning (inside and outside)
● Large storage capacity: up to 10,000 samples +3 histograms
● Internal thermal-sensitive printer or external printer.
● RS232 interface, PC connecting
Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode : double Channel + unique Hemoglobin test system
Sample volume: 9.8μL for Venous and capillary mode, 20μL for pre-diluted mode
Throughput: More than35 or 60 samples per hour, operate 24 hours per day, auto sleeping and waking-up functions
Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation langue: English
QC control : X-B, L-J, X , SD, CV %
Reference Value Setting : Male , Female, Children, Neonate
Input / output : RS232, parallel printer and keyboard
Print : Graphic thermal printer with various printing format, optional external printer
Power supply : 220 V ±22 VAC, 50±1Hz
Parameters : WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR
3 –histograms : WBC,RBC and PLT
Specification sheet
●3-part differentiation of WBC, 24 parameters, double channel counter
●8.4 inches color touch screen, Windows interface all testing parameter displayed simultaneously
●Waste full alarm automatically
●external printer such as Epson LQ-630k, Epson LQ-350, Epson M200/M201, HP P1007,HP 1020Plus
●up to 60 samples test per hour
● Electrical resistance for counting and SFT method of hemoglobin
● Low sample consumption : venous 9.8 uL, pre-diluted 20 uL for twice testing one time
● Windows operation system graphical buttons mouse and keyboard operation
● Double convolution and intelligent fitting
● Automatic diluting , Mixing , rinsing and clog clearing
● Automatically sample probe cleaning (inside and outside)
● Large storage capacity: up to 100,000 samples +3 histograms
● Internal thermal-sensitive printer.
● RS232 interface, PC connecting
Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT) Work mode : double Channel + unique Hemoglobin test system Sample volume: 9.8μL for Venous mode, 20μL for pre-diluted mode Throughput: More than 60 samples per hour, operate 24 hours per day, auto sleeping and waking-up functions Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data Operation langue: English QC control : X-B, L-J, X , SD, CV % Reference Value Setting : Male , Female, Children, Neonate Input / output : RS232, parallel printer and keyboard Print : Graphic thermal printer with various printing format, optional external printer Temperature : 18℃ - 30℃,wet ≤ 10-90% Power supply : 220 V ±22 VAC, 50±1Hz Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H ) Weight : 20 KG Precision Parameters linear rang
1. Who Are We?
We are based in Guangzhou, China, start from 2011,sell to Mid East (31.00%), Africa(23.00%),South America(18.00%), North America(13.00%) ,Southeast Asia(12.00%),Oceania(1.00%), Western Europe (1.00%),Central America(1.00%). There are total about 11-50 people in our office.
2. How Can We Guarantee Quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3.What Can You Buy From Us?
CT/MRI; Laboratory Equipment; Diagnostic Equipment; ICU Equipment; Theatre Equipment; Hemodialysis Equipment.
4. Why Should You Buy From Us Not From Other Suppliers?
1.13 years medical equipment leading exporter
2.One-stop service
3.High quality assurance system
4.Best Professional after-sell service with branch in Nigeria and Madagascar
5.Factory price
5. What Services Can We Provide?
Accepted Delivery Terms: FOB,CFR,CIF, EXW,FAS,CIP,FCA,DEQ;
Accepted Payment Currency: USD, EUR,CAD, AUD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A, MoneyGram, Credit Card,PayPal, Western Union, Cash,Escrow;
Language Spoken:English, Chinese,Spanish, Japanese, Portuguese, German, Arabic, French,Korean