Availability: | |
---|---|
Quantity: | |
MY-B030
Urine Analyzers: Urine analyzers are medical devices designed to perform automated testing of urine samples. They analyze various parameters, including pH, protein, glucose, ketones, bilirubin, blood, and leukocytes, which help diagnose a range of conditions such as kidney disease, urinary tract infections, and diabetes.
Product Advantage:
· Automation: Reduces manual labor and minimizes human error in the testing process.
· Fast Results: Delivers quick and reliable results, which are crucial for timely diagnosis.
· Comprehensive Testing: Provides a wide range of diagnostic information from a single urine sample.
· Ease of Use: User-friendly interface and minimal sample preparation make them suitable for use in various clinical settings.
Product Uses:
· Screening for urinary tract infections (UTIs)
· Monitoring kidney function
· Diagnosing diabetes and metabolic disorders
· Detecting pregnancy and other hormonal conditions
Product Operate Guide:
The operation of the machine is not done once and for all, and it is necessary to pay special attention to the state of the machine during each packaging process. In order to effectively manage and maintain the packaging machine and control the product quality, in addition to regular maintenance, the auxiliary personnel and feeding personnel of the equipment also need to follow the following operating procedures.
Auxiliary personnel
Turn on the power switch
Check whether the air pressure is sufficient (must reach 0.6Mpa)
Click the host to start, and check whether each action is working properly
Check and clean up each box room
Put the bag, load the material, put the material box
Click the host to start
The product that is packaged in vacuum for the first time should be checked whether the seal is firm, whether the suction is tight and through the water check(Must check vacuum chamber 1-10)
During the production process, check the product sealing and pumping conditions continuously
Every 2 hours after the machine runs, must be the top cover of the machine, bag clip, and funnel mouth, carried out with an air gun clean
The bag or material dropped on the machine, should be hooked out with a hook, do not take it by hand
Measuring item:K+、Na+、Cl-、Ca、pH
Calculating item:nCa、TCa
Measuring parameter:
(K+)
Measuring scope(mmol/L): 0.50~15.00
Resolving power(mmol/L): 0.01
Repeatabilit yerror: CV≤1.0%
(Na+)
Measuring scope(mmol/L): 30.0~200.0
Resolving power(mmol/L): 0.1
Repeatabilit yerror: CV≤1.0%
(Cl-)
Measuring scope(mmol/L): 30.0~200.0
Resolving power(mmol/L):0.1
Repeatabilit yerror: CV≤1.0%
(Ca2+)
Measuring scope(mmol/L): 0.10~5.00
Resolving power(mmol/L):0.01
Repeatabilit yerror: CV≤1.0%
pH
Measuring scope(mmol/L): 4.0~9.0
Resolving power(mmol/L):0.01
Repeatabilit yerror: CV≤1.0%
Measuring time: Measuring time: 25s
Time for sampling, measuring, washing and printing: 40s
Sample size:100μL(manual positioning 60μL)
Data storage:10000 ,It will refresh automatically if it is full
Communication:232 interface
Display:240×64 LCD
Printer: 58mm thermal printer
Power supply:AC220V±22V 50Hz 25W
Size :380mm×290mm×310mm
Weight:6Kg
Measuring method: ISE
Measuring condition :Temperature: 10℃~32℃
Relative humidity ≤85%
Type:Urine Analysis System
Test Items:10~14parameters
Memory Size:1000 test results
Test Principle:super-high luminosity cold light source reflection
Test Speed:120 tests/hour
Printing:Internal printer
Power:≤60W
Display Screen:LED screen
[Testing principle] Artificial intelligence + computer vision technology
[Scope of application] 10, 11, 12 and 14 parameters
[Test items] Glucose (GLU), Bilirubin (BIL), Ketone (KET), Leukocyte (LEU), pH, Ascorbic acid (VC), Protein (PRO), Urobilinogen (URO), Nitrite (NIT), Creatinine (CRE), Calcium (CAL), Microalbumin (MAL), Specific Gravity (SG), Blood (BLD)
[Data storage] Mass storage device; more than 1 million test results can be stored; test results can be queried according to the record number. [Display] 7 inch digital-touched screen [Data Communication] Can be connected to RS232 port, WIFI, network interface, sediment analysis system, management software of hospital (e.g. HIS, LIS) [Power supply] Alternating current 100-240V±10%, 50-60HZ, safe and reliable [Testing speed] 514 samples/h [Print method] built-in super-speed thermal printer [Working environment] Temperature 15-35℃, Humidity<85% [Power] 20VA [Weight] <5KGS
120tests/hr, 11 parameters, LCD screen, built-in printer
11 parameters
120 tests/hr
The color and limpidness can be input
Original matching urine strips for best accuracy
Performance:
LCD monitor
Adopt luminescence source with high brightness to minimize interference of the environmental light.
Date and patient number can be input.
Single test and continuous test are available
All the test data can be saved automatically.
Technical Specifications:
Wave length: 440-660nm
Throughput: 120 test/hr
Storage: 1000 patient data
Display: 240x64 LCD monitor
Printer: built-in thermal printer
Interface: RS232 serial
Calibration: fully automatic calibration
Condition: temperature: 0-40℃, humidity:5-90%
Power supply: 220VAC±10% 50~60Hz 30W
Dimension: 390(L)x320(W)x140(H)mm
Weight: 5Kg(net), 6.5Kg(gross)
Test Parameters:
PH, Nitrite, Protein
Glucose, occult blood, bilirubin
Urobilinogen, ketone
Specific gravity, Leukocytes
Ascorbic Acid
Color
Limpidness
Technical Data∶
·Parameters: pH, Nitrite, Specific Gravity, Ascorbic Acid, Blood, Glucose, Bilirubin, Urobilinogen,
Ketone, Leucocytes, Protein, Microalbumin, Creatinine
·Measurement Principle:dual wavelength reflectance method
·Measuring Wavelength: 3 LED Wavelength ( 550, 620, 720nm)
·Reaction time: 60 seconds
·Throughprt: Standard mode: 60 samples/hour
Fast mode:120 samples/hour
·Display: LCD screen
·Memory capacity: 4000 results
·Strip: URIT 10G/11G urine reagent strips(14G optional)
·Interface:Serial port(RS232), parallel port (For external printer),PS/2(For barcode reader, optional)
·Work condition:Environmental Temperature:15-30℃,RH:20%-80%
·Powersupply:100-240VAC,50/60Hz
·Dimension: 320mm x 300mm x 120mm
·Weight:3.5Kg
Features & Functions∶
·Friendly operation
·Internal calibration for sensitivity of strips
·Cold light source facility with long life and high stability.
·RS232 serial interface to host PC/LIS, barcode reader optional
·Compact size with large LCD display
Urinalysis Control
"
1.Principle of determination: by ultra-high degree of cold light reflection.
2.Scope of application : 8 item/10 item/ 11 item/ 12 item/14 item
3.Product determination : GLU/BIL/KET/SG/PH/BLD/PRO/URO/NIT/LEU/VC/CRE/CAL/MAL
4.Test speed: 60 copies of test/hour continuous test of 120/h
5.Recording method: thermal printer/ extermal print/ LCD screen display
6.Recording paper: 57mm thermal /non thermal paper
7.Test wavelength: 525-660 nm
8.Language choice: Chinese English
9.Working environment: 15-35 celsius degree, RH less than 85 percentage
10.Power: 50VA
FIA Analyzer is a fluorescence immunoassay analysing system which can help diagnose conditions such as cardiovascular diseases, pregnancy, infection, diabetes, renal injury and cancers, etc.
The platform provides reliable and quantitative results of various kinds of analytes in human blood and urine within several minutes.
Application: Cardiology, ER, ICU, Respriatory, Pediatrics, Laboratory, etc.
Test Item
•Cardiac
•Tumor
•Infection PCT,CRP(hsCRP+CRP)
•Diabetes & Renal Injury
•Hormone
•Ongoing
Application : Rapid Accurate POCT Quantitative Test
Principle : Fluorescence Immunoassay
Test items : "Infection Markers:CRP, PCT, CRP/PCT
Cardiac Markers: NT-proBNP, cTnI, Myo, CK-MB, H-FABP, cTn/Myo/CK-MB, cTn/NT-proBNP
Coagulation Marker: D-dimer
Renal Injury markers: MAU, CysC,
Diabetes Marker: HbA1c
Tumor Markers: AFP, PSA, CEA
Hormone Markers: βHCG, Prog,TSH, T3, T4"
Extended items : SAA,BNP, β2-MG, NGAL, fPSA,LH, FSH
Test mode : Standard Test and Quick Test
Channels : Single
Screening : 3.5 inch touch color screen
Memory : 10,000 tests
Inner printer : Yes
External printer : No
PC/LIS link : Yes
USB : No
Temperature Control Module(Heating system) : No
Barcode scanner : Dedicated
Auto calibration : Yes
Self-check : Yes
Power source : 100-240AC, 50-60Hz
Dimensions : 250*258*104mm
Weight : 2.5kg
Online software upgrade : No
Operating system : Windows CE
FEATURES :
CUSTOMIZED FUNCTION :
● Handheld operate ● 2.8 inch colorful touch screen
● Built-in virtual keyboard ● English
● Variety of detection model ● Automatically detect & storage the historical data
● Mass Memory (upload 、earchable & traceability)
● Battery duration 72 hours
● Update software automatically.
● One step operation , intelligent identification, get the test result
within 15 minute, Can compatibly detect nearly 30 kinds of immune markers.
LIST OF QUANTITATIVE RAPID TESTS
Inflammation markers:
A012D01 PCT
A022D01 CRP
A032D01 hs-CRP
A052D02 PCT-CRP
Thrombosis:
B012D01 D-Dimer
Vascular Inflammation:
C012D01 MPO
C022D01 LP-PLA2
Cadiovascular:
D012D01 CTnI
D022D01 H-FABP
D032D01 CK-MB
D042D01 Myo
D052D03 CtnI/CKMB/Myo Combo
D062D01 S100-β
E012D01 NT-proBNP
Renal Function:
F012D01 CysC
F022D01 NGAL
F033D01 MAU
Fertility:
G018D01 β-HCG
G026D01 IGFBP-1
G032D01 PAPP-A
G043D01 LH
G053D01 FSH
G062D01 PR
Diabetes care:
H022D01 C-Petide
H032D01 INS
Healthy Examination:
J032D02 PGI/PGII
J102D01 HP
J042D01 AFP
J052D01 PSA
J062D01 Fer
J072D01 BGP
J082D01 IgE
J092D01 Lp(a)
Method: Immuno-Chromatography
(Immunofluorecsence)
Dimensions: 261×241×115mm
Weight: 1.9 kg
Operating wavelength: 635±5 nm
Measurement range: 0~65535 mV
Time to Result: 3~5s
Memory: 10000 data
Operating System: Android System
Screen size: 7inch touch screen, 1024*600
Language: English and other upon request
Printer: Built in thermal printer
Battery: Built in lithium battery
Warranty: 1 Year
Connectivity: PC/LIS/HIS & WI-FI(soon)
Calibration: RFID & SD Card
Certificates: CFDA/CE/ISO
Multiplex test items
Routine maintenance: No requires
Automatic Barcode Identification
Patient information edit
On this platform, 11 parameters currently are available. Including:
5Cardiac markers-
cTnI, NT-proBNP, D-Dimer, the penal CKMB/Myo/cTnI
2 Inflammatory markers-
PCT, hs-CRP+CRP
4 Renal markers-
Cysc, mAlb. NGAL, β₂- MG
1 Diabetes HbA1c
To be lunched:
Thyroid markers TSH (sample available) and TSH/T3/T4, HCG+β, Vitamin-D, PSA, FOB, etc.
Specifications:
Detection method: Photometric detectior
Measurement:157.5*145.7*64.6mmi
Detection time ≤3min
Weight:622g
cv:≤ ±10%
Data storage:3000 results
Sample type:Peripheral or venous blood or serum
Display:4.3touch screen
Sample volume :≤ 45 uL
Adapter input AC100-240V.50/60Hz30VA, output5V,2A
Power supply :Adapter input AC100-240V.50/60Hz30VA, output5V,2A
Bult-in Lithium battery: DC3.7±0.3V
Storage environment :Temp:20 C~60 ℃; Rh:10% ~90% Operation environmen:Temp:15℃ ~35℃; Rh:<85%
Overall Performance
Equipment type Fully automatic discrete, STAT priority
Analysis rate Constant speed 160T/H (without ISE)
Test principle Colorimetry, turbidimetry
Analysis method End-point, 2 kinetics, fixed-time, etc. support single/double wavelength, linear and non-linear calibration
Sample System
Sample Tray 42 sample positions, random access of all samples
Sample Volume 2-50ul, 0.1ul increment
Sample probe Liquid level detection, the remaining detection, collision protection etc.
Sample Containers Sample cups, Micro tube, Original blood-collection tube, etc.
Reagent System
Reagent Tray 25 reagent positions
Reagent Volume R1:25-300ul, R2:10-150ul, 0.1ul increment
Reagent Probe Liquid level detection, the remaining detection, collision protection etc.
Reagent Refrigeration 4-15℃, independent power supply, 24-hour non-stop refrigeration
Reaction System
Reaction Tray Rotating tray, 120 cuvettes
Cuvette Reusable high quality cuvette, Optical diameter 6mm
Reaction Volume 180-500ul
Incubation system Bi-directional liquid-air device
Temperature 37℃±0.1℃ with real-time display
Optical System
Light source 12V35W halogen lamps, over 2000 hours
Photoelectron road after spectrophotometry
Wavelength 340,405,450,510,546,578,630,700nm
Absorbance range 0-3.500Abs
Resolution 0.0001Abs
Operating System
PC operating system Windows XP or above
Analysis control software English version graphical operating software
Report printing Report formats support the user-defined mode, QC and state information etc.
System connection RS-232
Working Conditions
Power supply AC 220V±22V, 50Hz±1Hz, power 1.5KVA
Ambient Temperature 15-30 ℃
Humidity 35-80%
Water consumption 5L/Hour
Dimension Bench top: 750mm*520mm*600m
Analysis system
Working mode: Discrete/random access
Test speed: test speed 180T/H (without ISE)
Test principle: Absorbance photometry, Turbidimetry
Methodology:End-point, Fixed-time, Kinetic, Single/Dual
reagent chemistries, monochromatic/bichromatic
Linear/non-linear multi-point calibration
The longest reaction time: 15 minutes
Minimum reaction volume: 150μl
Cuvettes material: plastics (quartz glass can be selected), 81
cuvettes have the function of automatically deducting reagent
and sample blanks
Linear range of absorbance: 0-3.8Abs
Halogen light source life time ≥ 2000 hours
Wavelength:340nm、405nm、450nm、510nm、546nm、
578nm、630nm、670nm
Refrigeration system: water medium uniform refrigeration
technology
Reagent storehouse temperature: 4-16℃
Reaction temperature: 37±0.2℃
Temperature fluctuation: ±0.1℃
Working Conditions
Temperature: 10℃ ~30℃
Humidity: ≤85%
Maximum Water Consumption:<12L
Power Supply: 200~240V 50/60HZ 600W
Dimension:834mm(w)×643mm(D)×756(H)
Net weight: 65KG
Gross weight: 98KG
PRODUCT FEATURES:
Mini Fully Auto Chemistry Analyzer Discrete/random access
STAT sample priority
asy to use
Internal computer with 13”displayer All-in-one machine
Automatic Washing
No Washing (Option : 150 B)
Test speed : Constant 150T/H
Dimension : 352mm(L)*600mm(W)*385mm(H)
Net weight : 27.8KG
REACTION:
40 cuvettes
25 sample positions+5 original tube
50 positions for reagent with cooling system
REAGENT:
25 bottles with volume of 6ml
25 bottles with volume of 24ml
LED light source with 8 channel transmissometry
SAMPLE HANDLING:
Liquid level detection / Collision protection
WORKING CONDITIONS:
Temperature:10~30℃
Humidity: ≤85%
Power Supply: AC 100~240V 50/60HZ
Water Consumption: ≤5L/H
Reaction/Reagent/Sample Handing:
81 cuvettes
24+5(Tube 12*100) sample positions
1 calibration position / 1 QC position / 1 ST position
54 positions for reagent
27 bottles with volume of 8ml
27 bottles with volume of 24ml
LED light source with 8 channel transmissometry,Rear
Spectrophotometry
Extra 1 channel scattering (Option : SL120 C)
Liquid level detection / Collision protection
High pressure water flush interior the probe
Working Conditions:
Temperature:10℃ ~30℃
Humidity: ≤85%
Power Supply: 100~240V 50/60HZ
Water Consumption: <5L
Test speed : Constant 120T/H
Dimension : 305mm(L) x 605mm(W) x 330mm(H)
Net weight : 22KG
Parameters:
Throughput:60 Tests/hour
Assay ltems:5 parts, 29 parameters, 3 histograms, 3D scattergram
Principle:Tri-angle laser scatter, Flow cytometry method, 3D scattergram analysis, lmpedancemethod for RBC and PLT counting, Cyanide free reagent for HGB test
Parameters:WBC, RBC,HGB,HCT,MCV,MCH,MCHC, RDW-SD, RDW-CV, PLT,MPV, PCT,PDW,P-LCRP-LCC,NEU%,LYM%,MON%,EOS%,BAS%,NEU#,LYM#,MON#,EOS#,BAS#4 Research parameter: ALY%,ALY#IG%IG#
Sample Volume:CBC+DIFF mode: S20ul
CBC mode: <10ul
Storage:100,000 results including histogram, scattergram and patient information
Interface:4 USB ports, 1LAN port Bi-direction LIS, support HL7 protocol, Internal RFID reader.
Power Supply:AC220V+10% 50/60Hz;110V+10% 60Hz;400VA
Package Size(W*D*H):670*590*790mm
Gross Weight:53kg
Reagent Package Size:330*330*330mm,400*290*240mm,400*290*240mm
Reagent Gross Weight:22kg, 2kg, 1kg
Throughput 60 samples/hour
Principle Tri-angle laser scattering and sheath flow for WBC differentiation and count, Impedance for RBC and PLT count, Colorimetry for HGB count
Aperture diameter RBC/PLT chamber: 70um
Parameters 26+4 parameters: WBC, Lym%, Mon%, Neu%, Bas%, Eos%, Lym#, Mon#, Neu#, Eos#, Bas#, RBC, HGB,
HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW-CV, PDW-SD, PCT, P-LCR, P-LCC, ALY%, ALY#, LIC%, LIC# (RUO)
Histograms 4 scattergrams, 2 histograms (including RBC, PLT histograms)
HGB lamp LED 530nm
Sample volume Whole blood mode: 20ul, Pre-diluted mode: 20ul
Unique design Built-in barcode scanner (Optional)
Calibration Manual, auto and fresh blood calibration
Counting modes Whole blood, capillary whole blood and prediluted
Sample analysis CBC+DIFF, CBC
Print Auto and manual print
Blockage clear High voltage, high pressure flush
Language English, Spanish, French, Portuguese, Italian and Russian
LIS connection Support Bi-directional LIS connection
Communication protocol HL7
Printer language PCL6
Storage 60,000 results with histograms
Reagent Standard configuration: Diluent/20L, DIFF Lyse/500ml, LH Lyse/200ml (2 Lyses inside the analyzer)
Cleanser Standard configuration: Probe cleanser/50ml
Input 10.4-inch touch screen, support mouse, keyboard, external barcode scanner
Output Built-in thermal printer, support external printer
Printer paper Φ50mm*58mm
Interface 1 DB9 serial port, 4 USB ports, 1 Network port (compatible with TCP/IP protocol)
Dimension 430(D)mm x 350(W)mm x 435(H)mm
Net weight 28KG
Work temperature 10-30°C
Power requirement 100~240 AC, 50/60Hz, 200VA
Relative humidity ≤85﹪
Atmospheric pressure 70.0kPa-106.0kPa
Detection of Reticulocyte
Quantitative detection of RET for capillary blood and
predilution blood.
Up to 7 report parameters.
Provide clinical reference information of RET maturity,
anemia treatment monitoring, and differential diagnosis.
Optical Platelet Detection
RET Detection with PLT-O parameter.
PLT-O ensures results more accurate through staining,
to avoid interferences.
Detection Technology:Fluorescence Staining & Flow Cytometry
Detection mode:
CBC
CBC+DIFF
CBC+RET
CBC+DIFF+RET
Sample mode:Whole Blood Mode, Low Value Leukocyte Mode, Predilution Mode, and Sample Research Mode
Sample volume:
Whole blood mode: 88ul
Predilution mode: 70ul
Throughput:
CBC+DIFF: 100T/H
CBC+RET: 83T/H
CBC+DIFF+RET: 83T/H
Reporting parameters (36 in total):
Leukocyte: WBC、NEUT(#,%)、LYMPH(#,%)、MONO(#,%)、EO(#,%)、BASO(#,%)、IG(#,%)
Erythrocyte: RBC、HGB、HCT、MCV、MCH、MCHC、RDW-SD、RDW-CV、NRBC(#,%)
Platelets: PLT、PDW、MPV、P-LCR、P-LCC、PCT
Reticulocyte: RET(#,%)、 IRF、 LFR、 MFR、 HFR、 RET-He
Linear range:
WBC: 0~500x109/L
RBC: 0 - 8.60×1012/L
HGB: 0 - 260g/L
PLT: 0~5000x109/L
Features:
5-part differentiation, 27 parameters, 3 DIFF scatter grams and 1 BASO scatter gram, 3 histograms for WBC, RBC and PLT.
Tri-angle semi-conductor Laser scatter combined with chemical dye method, advanced flow cytometry
Compact, powerful and affordable
Only 15ul sampling volume
Up to 60 samples per hour
3 counting modes: venous blood, capillary blood and pre-diluted
Capability to flag abnormal samples
Large storage capacity: up to 50,000 samples
Technical Specifications:
Principles
Impedance method for WBC, RBC, PLT counting
Cyanide-free reagent for Hemoglobin test
Flow Cytometry (FCM), Semi-conductor Laser scatter, chemical dye method, independent Basophil channel
Parameters
WBC, Lym%, Lym#,Mon%, Mon#,Neu%, Neu#,Eos%, Eos#, Bas%, Bas#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, PDW, MPV, PCT, and 4 research parameters LIC%, LIC#, ALY%, ALY#
3 DIFF scatter grams and 1 BASO scatter gram, 3 histograms
Throughput
Up to 60 samples per hour
Sample Volume
Whole Blood: 15ul, Pre-diluted: 20ul
Test Mode
CBC CBC+DIFF
Performance
Carryover Repeatability Linearity
WBC ≤0.5% ≤2.0% (4-15×109/L) 0.00-300×109/L
RBC ≤0.5% ≤1.5% (3.5-6.0×1012/L) 0.00-8.5×1012/L
HGB ≤0.5% ≤1.5% (110-180g/L) 0-250g/L
PLT ≤1.0% ≤4.0% (150-500×109/L) 0.00-3000×109/L
Data Storage Capacity
Up to 50,000 results including numeric and graphical information
Communication
LAN port supports HL7 protocol
Operating Environment
Temperature: 15oC-30oC
Humidity: 30-85%
Air Pressure: 70-106 kPa
Power Requirement
A.C. 100-240V, ≤300VA, 50/60Hz
Dimension and Weight
360mm(L) × 470mm(W) × 430mm(H)
Weight: 28kg
Parameters:
5-part WBC Differential
25 Reportable Parameters
2 Histograms
2 Scatter Grams
Abnormal Sample Alarm
Sample Mode:Whole Blood (Venous/Capillary), Pre-dilution
QC Methods:L-J QC, X-B QC
Power Supply:100-240 V~ 50/60 Hz
Weight:21 kg
Dimension:328 mm x 471 mm x 446 mm(LxWx H)
Data Storage:10000
Screen Type:10.4 inch Resistive Screen
Operating Conditions:18~30"C, <80% Relative Humidity, 75 kPa~106 kPa
Function: Automated WBC 3-differential, 22 parameters with 3 color histograms (WBC, RBC, PLT)
Principal: Electronic impedance, SFT method for hemoglobin
Throughput: ≥60T/H
Analysis Mode: Optional venous blood, anticoagulant blood and prediluted blood
Sample Volume: Anticoagulant whole blood ≤9.6µL, Anticoagulant capillary blood ≤9.6µL, prediluted capillary blood ≤20µL, the sample volume for repeating two times testing and avoiding second sampling
Working Mode: Automatic sampling, detecting automatic testing, furnished with dilutor, no need diluting outside. Automatic dispensing lyse and making second diluting automatically
Block-clearing: Soak and washing back and forth, high pressure burning. Boast the function of monitoring incomplete blockage
Alarm: Automated system diagnosis, self testing, fault alarm and reagent shortage alarm
Automated Maintenance: Automated washing during power on and power off, reducing the blockage rate
Standby Protection: 24 hours switch on, automatic sleep and wake up function
Storage: Large quantity test results storage, at least 400 thousand test results with comprehensive information. Extended SD memory supported.
Control Mode: Quality control mode of L-J, X-B and X-r. Westguard quality control regulation
Calibration Mode: Manual and automatic calibration available. Fresh blood calibration available also.
Reference Value Setting: Many reference value ranges (children, adult and the aged). The appropriate reference value range could be automatically selected according to the inputted age and sex.
Discriminator Function: Float and fix discriminator. Manual adjust available
Display: TFT LCD (Optional Touch Screen)
Input Mode: Standard mouse and keyboard. Optional bar code reader
Print Mode: Internal high-speed thermal printer. Optional connection with specified external printer. English printouts
Report Format: Many kinds of report format (not less than 8 kinds)
Reagents System: Open reagent system. No cyanogen reagents
●3-part differentiation of WBC, 23 parameters, single channel counter
●Volume measurement by time ,not wrong warning
●Adanced valve technology,long life
● RS232 interface, PC connecting
up to35/ 60 samples test per hour
● Electrical resistance for counting and SFT method of hemoglobin
● Low sample consumption : venous 9.8 ul, capillary 9.6 ul, pre-diluted 20 ul for twice testing one time
● 8.4” color TFT, Windows interface all testing parameter displayed simultaneously
● Windows operation system graphical buttons mouse and keyboard operation
● Double convolution and intelligent fitting
● Automatic diluting , Mixing , rinsing and clog clearing
● Automatically sample probe cleanning (inside and outside)
● Large storage capacity: up to 10,000 samples +3 histograms
● Internal thermal-sensitive printer or external printer.
● RS232 interface, PC connecting
Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 20 parameters and 3 color histograms (WBC, RBC, PLT)
Work mode : double Channel + unique Hemoglobin test system
Sample volume: 9.8μL for Venous and capillary mode, 20μL for pre-diluted mode
Throughput: More than35 or 60 samples per hour, operate 24 hours per day, auto sleeping and waking-up functions
Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data
Operation langue: English
QC control : X-B, L-J, X , SD, CV %
Reference Value Setting : Male , Female, Children, Neonate
Input / output : RS232, parallel printer and keyboard
Print : Graphic thermal printer with various printing format, optional external printer
Power supply : 220 V ±22 VAC, 50±1Hz
Parameters : WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB,HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV,PDW,PCT,L-PCR
3 –histograms : WBC,RBC and PLT
Specification sheet
●3-part differentiation of WBC, 24 parameters, double channel counter
●8.4 inches color touch screen, Windows interface all testing parameter displayed simultaneously
●Waste full alarm automatically
●external printer such as Epson LQ-630k, Epson LQ-350, Epson M200/M201, HP P1007,HP 1020Plus
●up to 60 samples test per hour
● Electrical resistance for counting and SFT method of hemoglobin
● Low sample consumption : venous 9.8 uL, pre-diluted 20 uL for twice testing one time
● Windows operation system graphical buttons mouse and keyboard operation
● Double convolution and intelligent fitting
● Automatic diluting , Mixing , rinsing and clog clearing
● Automatically sample probe cleaning (inside and outside)
● Large storage capacity: up to 100,000 samples +3 histograms
● Internal thermal-sensitive printer.
● RS232 interface, PC connecting
Main Technical Specifications
Methodology: Electrical resistance for counting, hemoglobin cyanide method and SFT method for hemoglobin
Parameter: 3-part differentiation of WBC; 21 parameters and 3 color histograms (WBC, RBC, PLT) Work mode : double Channel + unique Hemoglobin test system Sample volume: 9.8μL for Venous mode, 20μL for pre-diluted mode Throughput: More than 60 samples per hour, operate 24 hours per day, auto sleeping and waking-up functions Storage: up to 100000 sample results including histograms can be stored, convenient for inquiry and management of history data Operation langue: English QC control : X-B, L-J, X , SD, CV % Reference Value Setting : Male , Female, Children, Neonate Input / output : RS232, parallel printer and keyboard Print : Graphic thermal printer with various printing format, optional external printer Temperature : 18℃ - 30℃,wet ≤ 10-90% Power supply : 220 V ±22 VAC, 50±1Hz Dimension : 33 CM ( L ) * 38 CM ( W ) * 43 CM ( H ) Weight : 20 KG Precision Parameters linear rang
1. Who Are We?
We are based in Guangzhou, China, start from 2011,sell to Mid East (31.00%), Africa(23.00%),South America(18.00%), North America(13.00%) ,Southeast Asia(12.00%),Oceania(1.00%), Western Europe (1.00%),Central America(1.00%). There are total about 11-50 people in our office.
2. How Can We Guarantee Quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment.
3.What Can You Buy From Us?
CT/MRI; Laboratory Equipment; Diagnostic Equipment; ICU Equipment; Theatre Equipment; Hemodialysis Equipment.
4. Why Should You Buy From Us Not From Other Suppliers?
1.13 years medical equipment leading exporter
2.One-stop service
3.High quality assurance system
4.Best Professional after-sell service with branch in Nigeria and Madagascar
5.Factory price
5. What Services Can We Provide?
Accepted Delivery Terms: FOB,CFR,CIF, EXW,FAS,CIP,FCA,DEQ;
Accepted Payment Currency: USD, EUR,CAD, AUD,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A, MoneyGram, Credit Card,PayPal, Western Union, Cash,Escrow;
Language Spoken:English, Chinese,Spanish, Japanese, Portuguese, German, Arabic, French,Korean